16 days agoLocal fusing provides notable advantages, even without ring finals. In particular, one failed appliance doesn’t necessarily take out the whole circuit, and lower draw appliances can be more closely fused (e.g. 3A) reducing available fault energy.
Built in fuses protect only downstream of where the fuse is. The supply flex is therefore not protected, despite often being the most damaged part.